TECHNICAL DATA
System type: two-lane pusher furnace system (two different CHD treatments possible at the same time)
Commissioning: 2008, out of operation since February 2020.
Gas-heated with 33 charge places in the annealing chamber area and 6 places in the diffusion zone
Process gas: 2 endogas generators – 1 generator as back-up
Charging frame dimensions: 550 x 550 x 900 mm
The fully automatic system, consisting of:
preheating furnace
carburization zone
diffusion zone
oil quenching chamber
cleaning system
tempering furnace.
Annual maintenance by Aichelin.